Description
The AR-200/AR-400 series is a range of high-performance dynamic signal acquisition modules that are designed specifically for vibration monitoring and analysis. The maximum simultaneous sampling rate for each channel on the AR-200 and AR-400 is up to 200k-Hz and 125k-Hz respectively. The AR-200/AR-400 modules include a built-in 3mA excitation current to power the Integrated Electronics Piezo-Electric (IEPE) accelerometers and a 16-bit A/D converter.
The data acquired by the AR-200/AR-400 is saved on a Micro SD card that can be used for offline vibration analysis. A utility is also provided that can be installed on the Host PC so that the logger can be easily configured for different triggering modes, as well as changing the sampling rate, and scheduling the sampling time for various applications using the development tools. Consequently, the AR-200/AR-400 modules are recommended as your best choice for vibration monitoring and measurement.
Features
- 4 simultaneous, 16-bit resolution ADC.
- Support 2 or 4 IEPE input,and built-in 3 mA excitation current.
- AR-400 support sample rate: 125kHz、100kHz、50kHz.
- Max. Recording time:120 seconds.
- Flexible trigger modes: Push button trigger、Schedule trigger、analog threshold trigger、digital input trigger and utility remote trigger.
- Supports 4 to 32 GB micro SDHC type flash.
- 4 kV Contact ESD protection for any terminal.
- Wide range of power input (+10 to +30 VDC) and operating temperature (-25 to 75°C).
Specifications
LED Indicators | |
---|---|
Status |
1 x PWR 1 x DAQ 1 x SD |
Analog Input | |
---|---|
Channels | 4 (simultaneous sampling) |
Type | IEPE |
Range |
Voltage: ±10 V Current: 3 mA |
Resolution | 16 bit |
Sampling Rate | 5, 10, 20, 50, 100, 125 (kHz) |
Digital Input | |
---|---|
Channels | 2, Dry Contact: Source x 1, Wet Contact: Sink or Source x 1 |
ON Voltage Level |
Dry: Close to GND Wet: +10 VDC to +50 VDC |
OFF Voltage Level |
Dry: Open Wet: +4 VDC max |
Relay Output | |
---|---|
Channels | Form A x 1 |
Type | Power Relay |
Contact Rating |
5A@250 VAC (47 ~ 63 Hz) 5A@30 VDC |
Operate Time | 10 ms |
Release Time | 5 ms |
Electrical Endurance | 100,000 times min |
Mechanical Endurance | 20,000,000 times min |
Ethernet | |
---|---|
Ports | 1 x RJ-45, 10/100Base-T(X) |
Power | |
---|---|
Consumption | 4.3 W |
Mechanical | |
---|---|
Dimensions (mm) | 197 x 139 x 57 (W x L x H) |
Installation | Wall Mount |
Environment | |
---|---|
Operating Temperature | -25 ~ +75 °C |
Storage Temperature | -30 ~ 80 °C |
Humidity | 10 ~ 90% RH, non-condensing |
Technical