Description
The CL-200 series of data logger devices can be used to record CO, CO2, HCHO, TVOC, NH3, H2S, temperature, humidity and dew point information, including the date and time stamps, and are able to store up to 450,000 downloadable records.
Real-time data can be accessed from the CL-200 data logger from anywhere and at any time using the free Windows software, the iSO App, or the Android App, as long as they are connected to the same local network as the data logger.
Support is provided for common industrial protocols such as DCON, Modbus RTU, and Modbus TCP, as well as the emerging machineto-machine (M2M)/)IoT (Internet of Things) connectivity protocol – MQTT. The CL-200 data logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, ensuring trouble-free maintenance in distributed control systems.
Real-time data can be accessed from the CL-200 data logger from anywhere and at any time using the free Windows software, the iSO App, or the Android App, as long as they are connected to the same local network as the data logger.
Support is provided for common industrial protocols such as DCON, Modbus RTU, and Modbus TCP, as well as the emerging machineto-machine (M2M)/)IoT (Internet of Things) connectivity protocol – MQTT. The CL-200 data logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, ensuring trouble-free maintenance in distributed control systems.
Supports the MQTT Protocol for IoT Applications
Multi-platform Remote Access Software
Real-time data from the CL-200 data logger can be accessed from anywhere and at any time using the iAir Utility, the iOS or Android App, or via a regular web browser, as long as they are connected to the same local network as the data logger.
Simple and Powerful Utility
The iAir Utility can be used to configure the modules, monitor real-time data, group CL-200-E modules so that the status of distribution groups can be viewed and managed. The utility also allows the log data to be downloaded and exported to a .CSV file that can then be imported into any industry-standard software or spread sheet for analysis.
Features
- Able to record CO2, Temperature, Humidity and Dew Point Measurements
- Non-dispersive Infrared (NDIR) CO2 Sensor
- Up to 450,000 records with date and time stamps
- Supports the DCON, Modbus RTU/TCP, and MQTT Protocols
- Includes RS-485/Ethernet Communication Interfaces
- Relay Output for Alarm or IAQ Device Control
Specifications
Temperature Measurement | |
---|---|
Range | -10 ~ +50°C |
Resolution | 0.1°C |
Accuracy | ±0.6°C |
Humidity Measurement | |
---|---|
Range | 0 ~ 100% RH, Non-condensing |
Resolution | 0.1% RH, Non-condensing |
Accuracy | ±5% RH, Non-condensing |
CO2 Measurement | |
---|---|
Range | 0 to 9999 ppm (NDIR) |
Resolution | 1 ppm |
Accuracy | ±40 ppm ±3% of measured value |
Response Time | 120 seconds |
Warm-up Time | 5 minutes |
System | |
---|---|
Alarm | CO2/RH/Temperature |
Real Time Clock | Yes |
Data Logger | Yes, up to 450,000 records |
Relay Output | |
---|---|
Channels |
1 x Form A, SPST 30 VDC @ 16 A or 250 VAC @ 16 A |
COM Ports | |
---|---|
Ports |
1 x RS-485 1 x Ethernet |
Protocol |
DCON and Modbus/RTU (RS-485) Modbus TCP and MQTT (Ethernet) |
Ethernet | |
---|---|
Ports | 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators) |
Power | |
---|---|
Consumption |
Non-PoE: 1.5 W (Max.) PoE: 1.6 W (Max.) |
Powered from Terminal |