Description
These Solid-State Current Transducers convert a primary AC circuit current to a proportional Analog signal (0-5Vdc), which allows the Current Usage to be monitored by a wide range of Data Loggers plus Data Acquisition, SCADA and BMS Systems. They are used to monitor the current for Electrical loads such as pumps, conveyors, machines or fans.
The CSG-650 series of current sensors are self powered.
The CSG-650 series are Solid-core, which are ideal for new installations and they are available in three models:
- CSG-650-R1 : Switch-selectable range 0-10A, 0-20A or 0-50A
- CSG-650-R2 : Switch-selectable range 0-50A, 0-100A or 0-150A
- CSG-650-200 : 0-200A range
For retro-fit applications, please refer to the SCG-650 Split-core transducers.
IMPORTANT: Please specify the model required in the comments section of your order.
Features
- Solid-core for new installation
- Compact Size
- Self Powered
- 0-10Vdc proportional Output
-
Current Ranges available:
R1 = 0-10A, 0-20A, 0-50A switch selectable
R2 = 0-50A, 0-100A, 0-150A switch selectable
0-200A - 20.3mm diameter conductor hole
Specifications
-
Measurement Range(Model Specific):
R1 model; 0-10, 20, 50Amps
R2 model; 0-50, 100, 150Amps
0-200 Amps -
Maximum Input Current:
100 Amps for R1 model
150 Amps for R2 model
250 Amps for 200 Amp model -
Accuracy:
R1 & R2 versions: ± 2% FSO (5-100% of range)
200A Version: ± 1% FSO (5-100% of range) - Signal Output: 0-5Vdc
- Sensor Power: Self-powered
- Insulation Class: 600 Vac, insulated conductors
- Frequency: 50/60 Hz
- Response Time: 200 mS Typical, 0-90 %
- Output Load: 1MΩ typical
- Loading Error: add 0.5% error with 100KΩ
- Operating Temperature: -15 to 60 °C (5 to 122 °F)
- Operating Humidity: 5 to 90% RH non-condensing
- Terminal Block: 14 to 22 AWG
- Dimensions: 67 x 68.6 x 24.1mm
- Sensor Aperture: 20.3mm dia
- Enclosure Material: ABS/PC, UL94 V-0
- Agency Approvals: cULus Listed
Technical
CSG Series Current Transducers Datasheet
Applications
- Energy Usage
- Process monitoring
- Monitoring Motor/machine wear to schedule maintenance/improve reliability
For a complete solution, please talk to us about our Orchestrator SCADA Monitoring software and Data Acquisition products.