Description
The Micropower Data Logger is a universal device used for accurate, cost-effective and energy efficient applications used in environmental monitoring.
Remotely configurable inputs include voltage (0-10V), current (4-20mA) and pulse type signals as well as SDI-12 standard. Serial communication is enabled with the use of RS- 232 and optional RS-485 ports (Modbus RTU).
An integrated GSM/GPRS modem provides data transmission with user-selectable upload rates (1min – 24h). All measurements can be accessible through the intuitive web-based System or sent directly to the user’s server.
The Micropower Logging unit has an extremely high level of power efficiency (power consumption of <250μW in sleep mode) making the device perfect for off-grid applications and for long-term measurements.
An optional 30W PV panel can extend the lifetime of the logger and eliminate the need for battery replacement.
Standard Sensor Options
Wind Speed & Direction |
Temperature & Humidity (SDI-12) | Solar Radiation (Analogue) |
Rain Entry Level (unheated) - pulse Professional (unheated) - pulse Professional (heated) - pulse High resolution/accuracy (heated) SDI-12, Analogue, Pulse |
Temperature (NTC) | Barometric Pressure (SDI-12) |
NOTE: Requires external power. Please contact us for battery/solar options.
Features
- Excellent energy efficiency
- 4 configurable inputs (0-10V, 4-20mA, pulse)
- SDI-12 port for additional sensors (up to 15)
- RS-232 and RS485 (optional) with MODBUS RTU protocol
- Integrated GSM/GPRS modem for data transmission
- Integrated PV charger with MPPT
- Full online configuration (includes 12 month subscription)
- Free API's to allow data sending and interfacing to 3rd Party Server
- Optional board with additional SDI-12, PT100, 0-10V, 4-20mA and pulse inputs.
- Direct data transmission to user's server
- Threshold text and email alerts
Specifications
Inputs
- 4 x analogue/digital : 0-3V, 0-10V, 4-20mA, pulse counter
- 1 x SDI-12 :up to 15 values
- 1 x serial: RS232, MODBUS RTU
- Extension board (optional) : additional analogue, digital, SDI-12, pt100 inputs additional functionalities and components (LCD screen, WiFi, Bluetooth, etc.)
Communications
- Built-in modem: 2G (GSM/EDGE) 4 band frequencies 850/900/1800/1900MHz
- Antenna connector: MMCX
- Transmit Time Interval (TTI): defined by user in range: (1min…….24h)
- GSM network APN: user configurable
- modem working time: 20...30s typically
- Serial communication: RS232, Modbus RTU
- USB: USB-B for data retrieval and APN settings
Data Logger
- Measuring Time Interval (MTI): defined by user in range: (1min…24h)
- Internal memory: up to 50 000 records
- Logged maintenance parameters: Electronics’ temperature, power supply voltage, GSM signal, modem activity during last data transfer, cabinet door open (optional)
- Alarms (SMS, email): For all measured parameters and maintenance parameters
Power
- Input range: 5-30V
- Required input current: 0.2A
- Protection: OVP , OCP , reverse polarity, EMI/EMC filter
-
Power consumption (measured at 12V):
Standby mode: ≤ 250μW
Measurement mode: ≤ 20mW (sensors' power consumption not included)
Transmission mode: ≤ 360mW (depends on network signal strength) - PV panel charger: Built-in solar charger enables direct connection of a PV panel up to 5W
-
Approx. working time without battery (35Ah) replacement/recharging:
TTI – 60min, MTI – 10min >5 years
TTI – 10min, MTI – 10min >2 years
- Working temperature: -40°…+60°C
- Enclosure: ABS, IP65, IP67 (optional), IP68 (optional)
- Dimensions: 176x150x58mm
- Compliance information: Declaration of conformity (CE)
Technical
Applications
Hydrology
Meteorology
Rain Monitoring