The GW-7553 PROFIBUS DP to Modbus TCP Gateway allows ProfiBus DP master devices to communicate with Modbus TCP protocol devices such as a sensor, PLC or the ET-7000 and I-8KEx-MTCP series. It also supports Modbus ASCII / RTU protocol for connection to other Modbus devices, such as the M-7000 series.
Configuration of the GW-7553 is simple, as the device has a built-in web server, which allows the module to be setup using a web browser.

| Protocol & Hierarchy | DP-V0 & DP-V1 Slave |
| Supports PROFIBUS Transmission Rate (kbps) | 9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500, 3000, 6000, 12000 |
| Transmission Rate Setting | detected automatically |
| Max Input Data Length | 240 Bytes |
| Max Output Data Length | 240 Bytes |
| Address Setting | 0~126 set by DIP switch or EEPROM |
| Supports Modbus Mode | Master/Slave |
| Supports Modbus Format | RTU/ASCII/TCP |
| Ethernet | 10/100 Base-TX |
| Supports COM 1 Baudrate (kbps) | 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, 115.2 |
| Supports COM 1 Data Format | 7/8 data bits, No/Odd/Even parity, 1/2 stop bit |
| Indicators | PWR, ERR, and RUN LEDs |
| Network Isolation Protection | 2500 Vrms High Speed iCoupler |
| DC Isolation Protection | 3000 VDC on PROFIBUS side |
Web based configuration utility provides:
| Hardware | |||
| CPU | 80186, 80 MHz or compatible | ||
| SRAM/Flash/EEPROM | 512 KB / 512 KB / 16 KB | ||
| Watchdog | Watchdog IC CPU built-in | ||
| ESD Protection | 4 kV class A | ||
| PROFIBUS Interface | |||
| Controller | Profichip VPC3+C | ||
| Transceiver | ADI ADM2486 | ||
| Connector | 9-pin female D-Sub | ||
| Baud Rate (bps) | 9.6 k, 19.2 k, 45.45 k, 93.75 k, 187.5 k, 500 k, 1.5 M, 3 M, 6 M, 12 M | ||
| Transmission Distance (m) | Depend on baud rate (for example, max. 1200 m at 9.6 kbps ) | ||
| Isolation | 3000 VDC for DC-to-DC, 2500 Vrms for bus-to-logic | ||
| Protocol | DP-V0 & DP-V1 | ||
| UART Interface | |||
| COM | RS-232 (For updating firmware and configuration) | ||
| COM Connector | 5-pin screwed terminal block (TxD, RxD, RTS, CTS, GND ) | ||
| Baud Rate (bps) | 2400, 4800, 9600, 19200, 38400, 57600, 115200 | ||
| Data bit | 7, 8 | ||
| Stop bit | 1, 2 | ||
| Parity | None, Even, Odd | ||
| Ethernet Interface | |||
| Controller | 10/100Base-TX Ethernet Controller (Auto-negotiating, Auto_MDIX) | ||
| Connector | RJ-45 with LED indicator | ||
| LED | |||
| Round LED | PWR LED, RUN LED, ERR LED | ||
| Power | |||
| Power supply | Unregulated +10 ~ +30 VDC | ||
| Protection | Power reverse polarity protection, Over-voltage brown-out protection | ||
| Power Consumption | 2.5 W | ||
| Mechanism | |||
| Installation | DIN-Rail | ||
| Dimensions | 72mm x 33mm x 119mm (W x L x H) | ||
| Environment | |||
| Operating Temp. | -25 ~ 75 ? | ||
| Storage Temp. | -30 ~ 85? | ||
| Humidity | 5 ~ 95% RH, non-condensing |
Modbus Commands Supported
| 01 | Read Coil Status | Read the ON/OFF status of discrete outputs in the slave |
| 02 | Read Input Status | Read the ON/OFF status of discrete inputs in the slave |
| 03 | Read Holding Registers | Read the binary contents of holding registers in the slave |
| 04 | Read Input Registers | Read the binary contents of input registers in the slave |
| 05 | Force Single Coil | Write a single output to either ON or OFF in the slave |
| 06 | Preset Single Register | Write an integer value into a single register in the slave |
| 15 | Force Multi. Coils | Write each coil in the sequence of coils to either ON or OFF in the slave |
| 16 | Preset Multi. Registers | Write a block of contiguous registers in the slave |