PM-3112-240 Smart Power Meter Single phase, 2 loops (200A)


Price:
Sale price£260.00

Description

The PM-3000 series is a range of powerful and advanced Smart Power Meters that give you access to real-time electric usage for single-phase power measurement.

With its high accuracy (<1%, PF=1 ), the PM-3000 series can obtain reliable and accurate energy consumption readings from the monitored equipment in real time. These compact and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input currents up to 200 A). It operates over a wide input voltage range 10 ~ 300 VAC to allow worldwide compatibility. And with 2 channels of relay outputs, it can be linked with sirens or lights/indicators for alarm messages. They are available in versions supporting Modbus RTU, Modbus TCP or CAN bus protocols for easy integration. For ModbusTCP or CAN, please contact us.

NOTE: Installation must be carried out to any relevant standards by suitably qualified engineers.

Features

  • True RMS Power Measurements
  • Energy Analysis for 1P2W
  • Current Measurements Up to 200 A with Different CT Ratio
  • Voltage Measurements Up to 300 V
  • Clip-on CT for Easy Installation
  • W Accuracy Better than 1% (PF=1)
  • Supports RS-485, Ethernet or CAN bus Interface (different models)
  • Supports Modbus RTU, Modbus TCP or CANopen Protocol (different models)
  • Supports 2 Power Relay Output (Form A)

Specifications

Model PM-3112 PM-3114 PM-3112-MTCP PM-3114-MTCP PM-3112-CAN
PM-3112-CPS
PM-3114-CAN
PM-3114-CPS
AC Power Measurement
Wiring 1P2W-2CT 1P4W-4CT 1P2W-2CT 1P4W-4CT 1P2W-2CT 1P4W-4CT
Input Voltage 10 ~ 300 V
Input Current CT Φ10 mm (60 A); CTΦ16 mm (100 A); CTΦ24 mm (200 A)
Input Frequency 50/60 Hz
W Accuracy Better than 1% (PF=1)
Starting Current >0.03A ( 60A ), >0.05A (100A ), >0.09A( 200A )
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Data Update Rate 1 Second
Communication
RS-485 Protocol Modbus-RTU - -
Baud rate 9600,19200 (default), 38400, 115200;
DIP Switch Selectable
- -
Data format N,8,1 - -
Isolation 2500 VDC - -
Ethernet Protocol - Modbus TCP -
CAN Bus Protocol - - CAN Bus and CANopen
Baud rate - - 125 k (default), 250 k, 500 k, 1 M;
DIP Switch Selectable
Isolation - 2500 VDC
Alarm Output
Power Relay Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC
Power
Input Range +10 ~ 30 VDC +12 ~ 48 VDC +10 ~ 30 VDC
Power Consumption 2 W
Mechanical
Casing Plastic (Flammability UL 94V-0)
Dimensions (W x L x H) 127 mm x 105 mm x 33 mm
Module Installation

Estimate shipping

You may also like

Recently viewed