PM-3133-100-MTCP Smart Power Meter, Three phase, MTCP (60A)


Price:
Sale price£256.00

Description

The PM-3133 series is a range of powerful and advanced Smart Power Meters that give you access to real-time electric usage for three-phase power measurement.

With its high accuracy (<0.5%, PF=1 ), the PM-3000 series can obtain reliable and accurate energy consumption readings from the monitored equipment in real time. These compact and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input currents up to 200 A). It operates over a wide input voltage range 10 ~ 300 VAC to allow worldwide compatibility. And with 2 channels of relay outputs, it can be linked with sirens or lights/indicators for alarm messages. They are available in versions supporting Modbus RTU, Modbus TCP or CAN bus protocols for easy integration. 

NOTE: Installation must be carried out to any relevant standards by suitably qualified engineers.

Features

  • True RMS Power Measurements
  • Energy Analysis for 3P4W, 3P3W, 1P3W, 1P2W
  • Current Measurements Up to 200 A with Different CT Ratio
  • Voltage Measurements Up to 500 V
  • Clip-on CT for Easy Installation
  • W Accuracy Better than 0.5% (PF=1)
  • Supports RS-485, Ethernet or CAN bus Interface
  • Supports Modbus RTU, Modbus TCP or CANopen Protocol
  • Supports 2 Power Relay Output (Form A)

Specifications

Model PM-3133 PM-3133-MTCP PM-3133-CPS
AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Input Voltage 10 ~ 500 V
Input Current CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A)
Input Frequency 50/60 Hz
W Accuracy Better than 0.5% (PF=1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Data Update Rate 1 Second
Communication
RS-485 Protocol Modbus-RTU - -
Baud rate 9600,19200 (default), 38400, 115200; 
DIP Switch Selectable
- -
Data format N,8,1 - -
Isolation 2500 VDC - -
Ethernet Protocol - Modbus TCP -
CAN Bus Protocol - - CAN and CANopen
Baud rate - - 125 k (default), 250 k, 500 k, 
1 M; DIP Switch Selectable
Isolation - - 2500 VDC
Alarm Output
Power Relay Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC
Power
Input Range +12 ~ 48 VDC
Power Consumption 4 W
Mechanical
Casing Plastic
Dimensions (W x L x H) 127 mm x 105 mm x 33 mm
Module Installation DIN-Rail Mounting
CT Installation Clip-On

Estimate shipping