PMC-5151 Advanced Power Meter Data Logger


Price:
Sale price£559.00

Description

The PMC-5151 Power Meter Concentrator/Data Logger has a wide range of advanced features for energy analysis. Its features include:

  • Communication and data collection from up to 24 ModbusRTU or ModbusTCP Meters from the PM-2000 or PM-3000 range of Smart Power Meters.
  • Data Recording facility with real-time and historic graphs and statistics.
  • Can be configured to automatically send data to a server system for further analysis.
  • Build-in Web server for configuration and viewing of real-time and historic data using standard web browsers (includes Mobile version of the site). 
  • Flash HMI Editor for custom User Display
  • Seamless Integration with SCADA software or HMI Devices via Modbus RTU or TCP protocols.
  • Built-in IF-THEN-ELSE Rule Engine that enables logical rule creation for power demand management.
  • Scheduling facility for devices regulation and real-time alarm.
  • Connects to a wide variety of extra I/O devices, such as the XW-Boards, M-7000 I/O modules and standard Modbus RTU/TCP Slave modules, enabling extra sensors/ parameters to be monitored to give more context to the energy data. 

PMC-5151 Sample Configuration

 

Features

  • Built-in Web Server allows to set up the parameters of the front-end power meters and view power data via browsers
  • Immediately display power data in real-time trend or historical trend
  • Offer power data report generator function ( daily report and monthly report )
  • Built-in MicroSD card slot to store the power data
  • Recording rate from 1 minute to every 24 hours (default is every 5 minutes) instantaneous or average (5 second sampling)
  • Regularly send back power data files to back-end FTP Server software for data aggregation and analysis
  • Support Email & SMS message alarm notification function ( SMS messages have to work with ICP DAS GTM-201-USB)
  • Offer Flash HMI Tools for easy HMI interface design
  • Offer Modbus TCP/RTU Slave function that allows seamless integration with SCADA software
  • Arrange PMC Data Server to import power data to database system
  • Built-in IF-THEN-ELSE logic engine for thought-out power demand management
  • Provide Schedule function for operations of I/O modules (devices)
  • Support Modbus I/O modules that enable real-time control and management of the devices

Specifications

Model PMC-5151
System Software
Opration System Windows CE OS
.Net Compact Framework 2.0
Built-in Server PMC Runtime?Web server?FTP server
CPU Module
CPU 32-bit ARM CPU
SDRAM 128 MB
Flash 64 MB ( 32 MB for OS, 32 MB for System Disk and System Registry )
EEPROM 16 KB, Data Retention: 40 years; 1,000,000 erase/write cycles
Expansion Flash Memory The microSD socket with one 4 GB microSD card (support up to 16 GB microSDHC card)
RTC (Real Time Clock) Provide second, minute, hour, date, day of week, month, year
LED Indicators 1 LED for Power and Running
Rotary Switch Yes (0 ~ 9)
VGA and Communication Ports
VGA Yes?Resolution:640 × 480/800 × 600
Ethernet RJ-45 x 2, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED Indicator)
USB 1.1 (client) 1
USB 1.1 (host) 1, Connect to GTM-201-USB for SMS Function
COM 1 RS-232 (RxD, TxD and GND); non-isolated
COM 2 RS-485 (D+, D-); 2500 VDC; isolated
COM 3 RS-485 (D+, D-); 2500 VDC; isolated
Mechanical
Dimensions (W x L x H) 91 mm x 126 mm x 52 mm
Installation DIN-Rail Mounting
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +80 °C
Ambient Relative Humidity/td> 10 ~ 90% RH (non-condensing)
Power
Input Range +10 ~ +30 VDC
Isolated 1 kV
Power Consumption 4.8 W (0.2 A @ 24 VDC)

 

Technical

PMC-5151 Power Meter Concentrator / Data Logger datasheet

Function PMC-5141 PMC-5151
Power Meter Connection Allow connections to up to 16 ICP DAS Modbus RTU Power Meters Allow connections to up to 24 ICP DAS Modbus RTU or Modbus TCP Power Meters
I/O Module Connection Support XW-107 ? Support XW-107?XW-110?XW-304?XW-310
? Allow to connect to up to 8 remoteModbus I/O modules.(Modbus RTU or Modbus TCP)
System Configuration Website Yes
Connect to SCADA or HMI Devices Yes
(By Modbus TCP Protocol)
Yes
(By Modbus TCP or Modbus RTU Protocol)
Integration with PMC Data Server Yes
Power Data Display Real-time power data display Yes Yes (More Flexible)
Flash HMI for power data display Yes
Power Data Logger Real-time power data logging Yes
Logger file send back Yes (automatically)
Remote logger file management Yes
Historical power data report Yes
Power Demand Management Logical Operation Basic Operation Advanced Operation
(IF-THEN-ELSE Rule Operation)
Email Alarm Message Sending Yes (with SSL encryption)
SMS Alarm Message Sending Yes (SMS Alarm Sending) Yes (SMS Alarm Sending & SMS Command Execution)
I/O Module Operation Yes (Only XW-107) Yes ( Various I/O Modules supported)
Schedule Operation - Yes (Calendar/Repeat mode)
Time Synchronization Function(SNTP) - Yes

 

Applications

main_iconFactory


Electricity consumption always plays an important role in factory operations. With the limited availability of the energy sources, countries all over the world all seek to enforce legal regulations in energy saving and carbon reduction. As the cost of energy is getting higher and higher, factories are paying increasing attention to energy and resource optimization, to enable effective usage of the energy, not only reduce the electricity cost but to

Estimate shipping

You may also like