The Electronic Switch Pulse Input Adapter connects sensors with pulse outputs to loggers with smart-sensor inputs. This Smart Sensor is compatible with electronic switch closures such as FET or open-collector outputs, or CMOS-level logic signals with a maximum input frequency of 120 Hz (120 pulses per second).

For Contact Closure type meters, please click here for the S-UCD-M006 .

Features

  • Plug-n-play adapter for pulse output sensors
  • Automatically recognized by HOBO Energy Logger
  • 6m cable length (extension cables available)

Specifications

  • Maximum Input Frequency: 120 Hz (120 pulses per second)
  • Measurement Range: 0 – 65,533 pulses per logging interval
  • Resolution: 1 pulse
  • Lockout time: 45 µs ± 10%
  • Recommended Input Type: Electronic solid state switch closure or CMOS-level digital output (example: FET, opto-FET or open collector)
  • Preferred Switch State: Active low input Normally open
  • Edge Detection: Falling edge, Schmitt Trigger buffer (logic levels: low ≤ 0.6 V, high ≥ 2.7 V)
  • Minimum Pulse Width: 1 ms
  • Input/Output Impedance: 100 KΩ
  • Open Circuit Input Voltage: 3.3 V
  • Maximum Input Voltage: 3.6 V
  • User Connection: 24 AWG wires, 2 leads: white(+), black(-)
  • Operating Temperature Range: -40° to 75°C (-40° to 167°F)
  • Overall Cable Length: 6.5 m (21 ft.)
  • Housing: Weatherproof PVC housing protects input adapter electronics
  • Housing Dimensions: 14 x 0.95 cm (5.5 x 0.375 in.)
  • Weight: 310 g (11 oz.)
  • Bits per Sample 16
  • Number of Data Channels: 1
  • Measurement Averaging Option: No (reports the number of pulses over the logging interval)