Description
The HOBO UX90-001 State / Pulse / Event / Runtime data logger records state changes,electronic pulses and mechanical or electrical contact closures from external sensing devices.
This logger is ideal for monitoring energy consumption, mechanical equipment operation, and water and gas flow.
The HOBO UX90-001 State Logger is available in a standard 128 KB memory model (UX90-001) capable of 84,650 measurements and an expanded 512KB memory version (UX90-001M) capable of over 346,795 measurements.
IMPORTANT: Hoboware software is now available as a free download that will suffice for most applications. The PRO Version is available for extra analysis tools and use with a Data Shuttle. For the differences between the FREE and PRO versions, please refer to the BHW-Lite (Hoboware Free DVD & USB Cable) entry in the Recommended Products section (below). The download link is also available on the BHW-LITE Page.
Features
- One logger with 4 recording modes
- Internal reed switch can be used to determine when a door or window is open or closed
- Compatible with a wide range of external sensors
- Ships with 2.5 mm input cable (CABLE-2.5-STEREO)
Specifications
Measurements: Event, Kilowatt Hours (kWh), Motor On/Off, Pulse Input, Runtime, State Open/Closed, Water Flow
Internal Sensor
- Maximum State, Event, Runtime Frequency: 1 Hz
- Preferred Switch State: No magnet present (normally open)
External Input
- External Contact Input: Electronic solid state switch closure or logic driven voltage output
- Range: 0 to 3 V DC (USB powered), 0 to 2.5 V DC (battery powered)
- Max. Pulse Frequency: 50 Hz
- Max. State, Event, Runtime Frequency: 1 Hz
- Pulse, Event Lockout Time: 0 to 1 second in 100ms steps
- Solid State Switch Closure: Input Low: < 10kΩ; Input High: > 500kΩ
- Internal Weak Pull-up: 100 kΩ
- Input Impedance: Solid state switch closure: 100kΩ pull-up
Logger
- Resolution: Pulse: 1 pulse, Runtime: 1 second, State and Event: 1 State or Event
- Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
- Time Accuracy: +/- 1minute per month at 25°C (77°F)
- Battery Life: 1 year, typical with logging intervals greater than 1 minute and normally open contacts
-
Memory: UX90-001: 128 KB (84,650 measurements, maximum)
UX90-001M: 512 KB (346,795 measurements, maximum) - Download type: USB 2.0 Interface
- Download time: 10 seconds for 128kb, 30 seconds for 512kb
-
Logger operating range: Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification - LCD: LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
- Size: 3.66 x 5.94 x 1.52 cm (1.44 x 2.34 x 0.6 in.)
- Weight: 23 g (0.81 oz)
- Environmental Rating: IP50
Technical
UX90 Series time of use Loggers Datasheet
UX90-001 State/Pulse/Event/Runtime Data Logger datasheet
Applications
Door / Window Closures
Machine Runtime
Energy / Flow Monitoring